EasyManua.ls Logo

Mitsubishi C70

Mitsubishi C70
536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IV - 76
Appendix 7. Explanation of Alarms
Appendix 7.3 Servo/Spindle Alarms (S)
S02 Initial parameter error : PR 2305 (Axis name)
Details
No servo option is found.
The adaptive filtering is an optional function.
Remedy
Check that all the related parameters are specified correctly.
sv027:SSF1/aflt
S02 Initial parameter error : PR 13001-13256 (Axis name)
Details
Parameter error
The spindle parameter setting data is illegal.
The alarm No. is the No. of the spindle parameter where the error occurred.
Remedy
Check the descriptions for the appropriate spindle parameters and correct them.
Refer to Alarm No.37 in Spindle Drive Maintenance Manual.

Table of Contents

Related product manuals