IV - 178
Appendix 7. Explanation of Alarms
Appendix 7.12 Program Errors (P)
P503 Illegal G110 axis
Details
- The commanded axis does not exist.
- The mixed control (cross axis control) (G110) was commanded to the axis for which the
mixed control (cross axis control) is disabled.
- The number of axes included in the mixed control (cross axis control) (G110) command is
exceeding the maximum number of axes per part system.
Remedy
- Correct the program.
P600 NO AUTO TLM.
Details
An automatic tool length measurement command (G37) was issued though it is out of
specifications.
Remedy
- Check the specifications.
P601 NO SKIP SPEC.
Details
A skip command (G31) was issued though it is out of specifications.
Remedy
- Check the specifications.
P602 NO MULTI SKIP
Details
A multiple skip command (G31.1, G31.2 or G31.3) was issued though it is out of
specifications.
Remedy
- Check the specifications.
P603 SKIP SPEED 0
Details
The skip speed is "0".
Remedy
- Specify the skip speed.
P604 TLM ILL. AXIS command
Details
No axis was specified in the automatic tool length measurement block. Otherwise, two or
more axes were specified.
Remedy
- Specify only one axis.
P605 T-CMD IN BLOCK
Details
The T code is in the same block as the automatic tool length measurement block.
Remedy
- Specify the T code before the automatic tool length measurement block.