Programming
 10-03-01 ETU Setup – ESI Terminal Type (B1)
The system automatically assigns the terminal type (10) for the port which has a DSS console
installed.
 15-02-08 Multiline Telephone Basic Data Setup – Automatic Handsfree
Set to 1 for a DSS Console to have one-touch operation. If set to 0, the user needs to lift the
handset before pressing a DSS key for the call to complete.
 20-06-01 Class of Service for Extensions
Assign Class of Service (1~15) to extensions.
 20-13-06 Class of Service Options (Supplementary Service) – Automatic Off-Hook Signaling
(Automatic Override)
Allow a busy extension user to manually (0) or automatically (1) receive off-hook signals.
 20-13-49 Class of Service Options (Supplementary Service) – BLF Indication on CO Incoming State
(Version 1600 or higher required)
Turn Off (0) or On (1) the BLF Indication when a Ring Group call rings a station. This
assignment does not apply to single line telephones.
 20-17-01 Operator Extension – Operator’s Extension Number
Define the extension numbers used as operators.
 30-01-01 DSS Console Operating Mode
Set the system DSS Consoles mode. The available options are Business Mode (0), Hotel Mode