ProBlue Flex 400/480 Volt Transformer
F-16
Part 1128350_02
E 2020 Nordson Corporation
Sub-base Removal (contd)
3. SeeFigureF-12.Disconnectthegroundwirefromthechassisto
sub-base by doing the following:
a. Remove the chassis cover plate screw and then remove the cover
plate.
b. Locate the ground wire and disconnect.
3
4
5
6
1
2
Figure F-12 Disconnecting ground wire
1. Sub-base
2. Chassis
3. Chassis cover plate screw
4. Cover plate (removed)
5. Sub-base ground wire
connection
6. Chassis ground wire
connection
4. Push the melter backwards to disengage the locking tabs on the
sub-base.
5. Lift the melter from the sub-base to remove.