OHAUS Explorer EX423N/E - User Manual

OHAUS Explorer EX423N/E
164 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Explorer
®
Balances
Instruction Manual
w ww . . co m
information@itm.com1.800.561.8187

Table of Contents

Questions and Answers

  • D
    Destiny GatesAug 13, 2025
    How to fix 'Cannot calibrate' error on OHAUS Explorer EX423N/E Scales?
    • H
      Heidi CampbellAug 13, 2025
      If the OHAUS Scales display 'Cannot calibrate', first ensure that the Calibration Menu is not locked; if it is, turn the Calibration menu lock off. Also, check if LFT is turned on; if so, turn LFT off. An unstable environment can also prevent calibration, so move the balance to a more suitable location. Finally, verify that you are using the correct calibration masses; if not, use the correct ones.
  • C
    Connie RamirezAug 16, 2025
    Why OHAUS Scales will not turn on?
    • W
      williamschultzAug 16, 2025
      If your OHAUS Scales are not turning on, it could be due to a lack of power. Verify the connection and voltage to ensure the balance is receiving power.
  • D
    Dylan SimsAug 20, 2025
    How to resolve 'Invalid Piece Weight' error on OHAUS Explorer EX423N/E Scales?
    • J
      Jennifer MasonAug 21, 2025
      If your OHAUS Scales display 'Invalid Piece Weight', it means the average piece weight is too small. To resolve this, increase the average piece weight.
  • R
    Robyn UnderwoodAug 25, 2025
    What to do if OHAUS Explorer EX423N/E show 'Operation Timeout'?
    • M
      Mrs. Samantha MathewsAug 25, 2025
      If your OHAUS Scales display 'Operation Timeout', it means the weight reading is not stable. To resolve this, move the balance to a more suitable and stable location.
  • G
    gkleinAug 28, 2025
    Why are my OHAUS Explorer EX423N/E showing poor accuracy?
    • J
      Jennifer WatersAug 28, 2025
      If your OHAUS Scales are showing 'Poor accuracy', it could be due to improper calibration. In this case, perform a calibration. Alternatively, an unstable environment may be the cause; move the balance to a more suitable location.
  • N
    Nicholas RyanAug 31, 2025
    What to do if I cannot change menu settings on OHAUS Explorer EX423N/E Scales?
    • N
      Nicole CoxAug 31, 2025
      If your OHAUS Scales display 'Cannot change menu settings', it could be because the sub-menu is locked. Unlock the sub-menu to regain access to the settings. Another possibility is that LFT is set to on; in this case, turn LFT off.
  • C
    Chelsey LewisSep 4, 2025
    What does 'Low Reference weight' mean on OHAUS Explorer EX423N/E Scales?
    • S
      scottbushSep 4, 2025
      If the OHAUS Scales display 'Low Reference weight', this indicates that the reference weight is too small. Increase the sample size to resolve this issue.
  • M
    Mallory HernandezSep 8, 2025
    What to do if OHAUS Explorer EX423N/E display 'Busy (tare, zero, printing)'?
    • J
      Joshua WilsonSep 8, 2025
      If the OHAUS Scales display 'Busy (tare, zero, printing)', wait until the current operation is completed.

Summary

Introduction to Explorer Balances

Safety Precautions

Essential safety guidelines and warnings for operating and handling the Explorer balance to prevent injury or damage.

Installation and Initial Setup

Location, Leveling, and Power Connection

Guidance on selecting an optimal location, leveling the balance, and connecting the power supply for accurate operation.

Initial Calibration Procedure

Steps for performing the initial calibration of the balance to ensure accurate weighing results.

Operating the Explorer Balance

Explorer Balance Applications

Weighing

Using the balance for basic weighing, including edit settings, application setup, and saving data.

Menus and System Configuration

Calibration Procedures

Detailed explanation of different calibration methods including Internal, Span, and User calibration.

Technical and Regulatory Information

Legal for Trade Requirements

Information on setting up, verifying, and sealing the balance for trade and legally controlled applications.

Troubleshooting and Maintenance

Guidance on common issues, troubleshooting steps, and routine maintenance procedures for the balance.

OHAUS Explorer EX423N/E Specifications

General IconGeneral
Capacity420 g
Readability0.001 g
DisplayLCD with backlight
Linearity±0.002 g
Repeatability (Std. Dev.)0.001 g
CommunicationUSB, RS232
Operating Temperature Range10 °C to 40 °C
InterfaceUSB, RS232
Weighing Unitsg, oz, dwt, ct, N
Power SupplyAC Adapter
Stabilization Time1.5 s
CalibrationAutomatic internal calibration
Humidity10% - 80% RH, non-condensing