45762101TH Rev.1
3-5
Item1 Item2 Item3 Item4 Item5 Value
Default
value
ODA
Default
value
OEL
Default
value
JP
Notes
Password Scanner
Maintenance
Adjust Mech. Adjust FB
Motor
FB Drive
Current
10 ~ 1400 [mA] 300 [mA] 300 [mA] Only for engineering test
Connect a panel or PC and set the electric current value of the scanner motor.
FB Keep
Current
10 ~ 1400 [mA] 50 [mA] 50 [mA]
Adjust ADF
Motor
ADF Drive
Current 1
10 ~ 1400 [mA] 840 [mA] 840 [mA]
ADF Drive
Current 2
10 ~ 1400 [mA] 740 [mA] 740 [mA]
ADF Drive
Current 3
10 ~ 1400 [mA] 700 [mA] 700 [mA]
ADF Drive
Current 4
10 ~ 1400 [mA] 650 [mA] 650 [mA]
ADF Keep
Current
10 ~ 1400 [mA] 200 [mA] 200 [mA]
Adjust CIS Adjust CIS simple
R continuous
G continuous
B continuous
All continuous
Only for engineering test
Sequentially light the designated RGB colors and check them during calibration
configuration duties.
Move the CIS to the standard position.
In the position moved to, sequentially light R, followed by G and B in the same
manner.
Light each color for approximately 3 seconds.
Display "Testing" during execution?
→
On the panel, display "CIS light testing" and "Cancel."
Check CIS 300dpi
600dpi
---Results Displayed---
CCD_SIG9_WID_H 0x000000
CCD_SIG2_WID_H 0x000000
Only for engineering test
Check CIS maintenance displays the exposure time at each resolution.
When resolution is set, scanner calibration is conducted at that
resolution and the
following results are displayed:
Red-1
Red-2 (No indication)
Green-1
Green-2 (No indication)
Blue -1
Blue-2 (No indication)
Lsync
Note : CIS exposure time varies with resolution.