45762101TH Rev.1
3-6
Item1 Item2 Item3 Item4 Item5 Value
Default
value
ODA
Default
value
OEL
Default
value
JP
Notes
Password Scanner
Maintenance
Adjust CIS Set CIS
Exposure
time
0 ~ 4294967295 Only for engineering test
Change LED exposure time settings, and then read the document using
PC Scan.
Reading implemented for the LED exposure time in the settings, without
conducting
calibration.
A warning is displayed when a value greater than the Lsync cycle has
been set.
Settings are shown below.
Red-1
Red-2 (No indication)
Green-1
Green-2 (No indication)
Blue -1
Blue-2 (No indication)
Lsync
AFE
Parameter
R3 (03h)
R32 (20h)
R33 (21h)
R34 (22h)
R35 (23h)
R36 (24h)
R37 (25h)
R38 (26h)
R39 (27h)
R40 (28h)
R41 (29h)
R42 (2Ah)
R43 (2Bh)
Only for engineering test
Change AFE (IC) register settings (3 - 9 settings).
Then, read the document using PC Scan.
W : Display message showing that settings are complete.
R : Display read value.
Mechanical
Test
ADF Test Simplex/
Duplex
Simplex
Duplex
Conduct mechanical testing (without reading an image).
ADF : Test moving original document (stops when set document has been moved)
May choose from single- or double-sided feeding.
FBS : CIS moving test (stops after designated number of operations)
Use fastest read speed (30 cpm).
Display "Testing" during execution?
→
On the panel, indicate current number of executions using the message "Test no.
xxx underway."
Speed Mono 300 x 300dpi
Mono 600 x 600dpi
Color 300 x 600dpi
Color 600 x 600dpi
Execute --Results--
Test no. xxx underway