Diagnostic information 2-17
109.02 Service
Black Printhead
The black printhead failed to complete
servo.
Perform a POR. If the problem persists, go
to “Printhead service check” on
page 2-57
109.03 Service
Black Printhead
The black printhead mirror motors
failed to achieve lock.
Perform a POR. If the problem persists, go
to “Printhead service check” on
page 2-57
109.04 Service
Black Printhead
The black printhead mirror motors lost
PLL motor lock.
Perform a POR. If the problem persists, go
to “Printhead service check” on
page 2-57
109.05 Service
Black Printhead
Failure reading NVRAM from
printhead.
Perform a POR. If the problem persists, go
to “Printhead service check” on
page 2-57.
109.08 Service
Black Printhead
The black laser showed bad in EMS
testing.
Perform a POR. If the problem persists, go
to “Printhead service check” on
page 2-57.
109.11Service
Black Printhead
Failure writing data to printhead Perform a POR. If the problem persists, go
to “Printhead service check” on
page 2-57.
109.12 Service
Black Printhead
Failure reading data from the printhead Perform a POR. If the problem persists, go
to “Printhead service check” on
page 2-57.
109.13 Service
Black Printhead
Printhead declared error Perform a POR. If the problem persists, go
to “Printhead service check” on
page 2-57.
122.xx Service
Fuser Error
Fuser error Go to “Fuser service check” on
page 2-39.
122.01 Service
Fuser Error
EWC error—Attempting to print with
estimated power at or below minimum
power.
Go to “Fuser service check” on
page 2-39.
122.02 Service
Fuser Error
Fuser over temperature. Go to “Fuser service check” on
page 2-39.
122.03 Service
Fuser Error
Fuser open thermistor check failed. Go to “Fuser service check” on
page 2-39.
122.04 Service
Fuser Error
EWC Error—Did not reach EWC start
temperature in time.
Go to “Fuser service check” on
page 2-39
122.05 Service
Fuser Error
EWC Error—Did not change
temperature within expected time.
Go to “Fuser service check” on
page 2-39
122.06 Service
Fuser Error
EWC Error—Did not reach EWC stop
temperature in time.
Go to “Fuser service check” on
page 2-39
930.09 Service
LVPS
Fuser zero crossings out of range.
Zero crossing detected.
Go to “Fuser service check” on
page 2-39.
122.10 Service
Fuser Error
Fuser failed to warm up. Go to “Fuser service check” on
page 2-39.
122.11 Service
Fuser Error
Fuser under temperature error while in
standby.
Go to “Fuser service check” on
page 2-39.
122.12 Service
Fuser Error
Fuser under temperature error while
printing.
Go to “Fuser service check” on
page 2-39.
Service error messages (1XX, 8XX and 9xx) (continued)
Error code Description Action
Y112730-2

Table of Contents

Other manuals for Olivetti d-Color MF920

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Olivetti d-Color MF920 and is the answer not in the manual?

Olivetti d-Color MF920 Specifications

General IconGeneral
BrandOlivetti
Modeld-Color MF920
CategoryAll in One Printer
LanguageEnglish

Related product manuals