Chapter 5
5-24
Remote I/O Functions
● Input Bit Details
Note 1. The function set in the multi-function output selection parameter is enabled.
3G3MV: The function set in parameter n057 to n059 (function selection for multi-function outputs 1
to 3) is enabled.
3G3RV/3G3PV/3G3FV:
The function set in parameter H2-01 to H2-03 (function selection for the multi-function con-
tact output and multi-function outputs 1 and 2) is enabled.
Note 2. The P lock function (position lock or zero-servo function) is valid only for a 3G3FV Inverter
operating with flux vector control. This bit is not used with other Inverters or control modes.
Name Function
During run 1: During run
Zero speed 1: Zero speed
During reverse run 1: During reverse run
During reset input 1: During reset input
At reference 1: At reference
Inverter ready 1: Inverter ready
Alarm (minor fault) 1: Alarm (minor fault)
Fault 1: Fault
Operation fault 1: Operation fault
Power interruption
recovery
1: Recovered from a momentary power interruption
Local/remote 1: Remote mode
Multi-function contact
output
1: Function specified in n057/H2-01 (See note 1.)
Multi-function output 1 1: Function specified in n058/H2-02 (See note 1.)
Multi-function output 2 1: Function specified in n059/H2-03 (See note 1.)
P lock completion 1: Position lock engaged (See note 2.)