Chapter 1
1-16
Functions and System Configuration
1-5-3 DeviceNet Communications Specifications
Operating
environ-
ment
Compatible
OS
Windows 95, 98, ME,
NT 4.0, 2000, or XP
Windows 95, 98, ME,
or NT 4.0
Windows 95, 98, 2000,
or XP
Minimum com-
puter require-
ments
IBM PC/AT or compatible (OS requirements may be stricter than the fol-
lowing.)
CPU: 166 MHz Pentium min.
Memory: 32 MB min.
Hard disk: 15 MB min. free space
Connec-
tion
method
Dedicated
interface
Sold separately ISA Board PCMCIA Card
Serial Connect from the computer’s COM port through a CS/CJ-series PLC.
(This connection is possible when a CS/CJ-series DeviceNet (Master)
Unit is being used.)
Ethernet Connect from the computers Ethernet port through a CS/CJ-series
PLC’s Ethernet.
(This connection is possible when a CS/CJ-series DeviceNet (Master)
Unit is being used.)
Relation to Network Using a dedicated interface: Connect directly to DeviceNet.
Operates as one node on the Network, requires one node address,
and only one Configurator can be connected to the Network.
The Configurator can be disconnected from the Network after remote I/
O has been allocated.
Using a serial or Ethernet connection:
Possible only when a CS/CJ-series DeviceNet (Master) Unit is being
used.
A DeviceNet node address is not required. (Connects through the
DeviceNet (Master) Unit.)
A node address is not allocated, so the Configurator can be connected
or disconnected freely. (There are some limitations compared to a
direct DeviceNet connection through a dedicated interface. For exam-
ple, the refreshing interval for PV monitoring is much slower that it is
with a direct connection.)
Item Specifications
Communications protocol DeviceNet
Supported connections (com-
munications)
Remote I/O
Master/Slave connection (Poll, Bit-strobe, COS, or Cyclic)
Explicit messages
Explicit connection
Both conform to DeviceNet specifications.
Connection forms Combination of multi-drop and T-branch connections (for trunk and drop
lines)
Baud rate 500 Kbps, 250 Kbps, or 125 Kbps (switchable)
Communications media Special 5-wire cables (2 signal lines, 2 power lines, and 1 shield line)
Thick Cable: DCA2-5C10 (100 m)
Thin Cable: DCA1-5C10 (100 m)
Dedicated interface --- 3G8F5-DRM21-E 3G8E2-DRM21-EV1