Chapter 10
10-38
Appendices
■ Function Group 3 (n080 to n119)
Con-
stant
Regis-
ter num-
ber
(hex)
Class 64 (hex) Name Setting
range
Setting
unit
Default
setting
Write
during
opera-
tion
In-
stance
At-
tribute
n080 0150 01 50 Carrier frequency selection 1 to 4, 7
to 9
1Differs
with
capacity.
No
n081 0151 01 51 Momentary power interruption com-
pensation
0 to 210No
n082 0152 01 52 Number of fault retries 0 to 10 1 0 No
n083 0153 01 53 Jump frequency 1 0.00 to
400.0
0.01 Hz 0.00 No
n084 0154 01 54 Jump frequency 2 0.00 to
400.0
0.01 Hz 0.00 No
n085 0155 01 55 Jump frequency 3 0.00 to
400.0
0.01 Hz 0.00 No
n086 0156 01 56 Jump width 0.00 to
25.50
0.01 Hz 0.00 No
n087 0157 01 57 Cumulative operation time selection 0, 1 1 0 No
n088 0158 01 58 Cumulative operation time 0 to 6550 1
(10 h)
0No
n089 0159 01 59 DC injection braking current 0 to 100 1% 50 No
n090 015A 01 5A DC injection braking-to-stop time 0.0 to
25.5
0.1 s 0.5 No
n091 015B 01 5B Startup DC injection braking time 0.0 to
25.5
0.1 s 0.0 No
n092 015C 01 5C Stall prevention during deceleration 0, 1 1 0 No
n093 015D 01 5D Stall prevention level during accelera-
tion
30 to 200 1% 170 No
n094 015E 01 5E Stall prevention level during operation 30 to 200 1% 160 No
n095 015F 01 5F Frequency detection level 0.00 to
400.0
0.01 Hz 0.00 No
n096 0160 01 60 Overtorque detection function selection
1
0 to 410No
n097 0161 01 61 Overtorque detection function selection
2
0, 110No
n098 0162 01 62 Overtorque detection level 30 to 200 1% 160 No
n099 0163 01 63 Overtorque detection time 0.1 to
10.0
0.1 s 0.1 No
n100 0164 01 64 UP/DOWN frequency selection 0, 1 1 0 No
n101 0165 01 65 Speed search deceleration time 0.0 to
10.0
0.1 s 2.0 No
n102 0166 01 66 Speed search level 0 to 200 1% 150 No
n103 0167 01 67 Torque compensation gain 0.0 to 2.5 0.1 1.0 Yes
n104 0168 01 68 Torque compensation primary delay
time constant
0.0 to
25.5
0.1 s 0.3 No
n105 0169 01 69 Torque compensation core loss 0.0 to
6550
0.1 W Differs
with
capacity.
No
n106 016A 01 6A Rated motor slip 0.0 to
20.0
0.1 Hz Differs
with
capacity.
Ye s
n107 016B 01 6B Motor phase-to-neutral resistance 0.000 to
65.50
0.001 Ω Differs
with
capacity.
No