Chapter 10
10-34
Appendices
● Input Terminal Status: Register Number 002B Hex
● Inverter Status: Register Number 002C Hex
● Output Terminal Status: Register Number 002D Hex
● Inverter Status 2: Register Number 002E Hex
Bit Content
0 Multi-function input 1 terminal S1 (1: ON)
1 Multi-function input 2 terminal S2 (1: ON)
2 Multi-function input 3 terminal S3 (1: ON)
3 Multi-function input 4 terminal S4 (1: ON)
4 Multi-function input 5 terminal S5 (1: ON)
5 Multi-function input 6 terminal S6 (1: ON)
6 Multi-function input 7 terminal S7 (1: ON)
7 to 15 Not used.
Bit Content
0 During Run (1: During Run)
1 Zero speed (1: zero speed)
2 Frequency agree (1: frequency agree)
3 Warning (minor fault) (1: alarm)
4 Frequency detection 1 (1: output frequency
≤ n095)
5 Frequency detection 2 (1: output frequency
≥ n095)
6 Inverter ready (1: ready)
7UV (1: UV)
8 Baseblock (1: during baseblock)
9 Frequency reference mode (1: not communications)
10 RUN command mode (1: not communications)
11 Overtorque detection (1: over torque detection)
12 Not used.
13 Fault retry (1: fault retry)
14 Fault (1: fault)
15 Communications timeover: over 2 s without normal communications
(1: communications timeover detected)
Bit Content
0 Multi-function contact output terminal MA (1: ON)
1 Multi-function photocoupler output 1 terminal P1 (1: ON)
2 Multi-function photocoupler output 2 terminal P2 (1: ON)
3 to 15 Not used.
Bit Content
0 Frequency reference loss (1: loss)
1 to 15 Not used.