Chapter 10
10-5
Appendices
Restarting Communications
The Communications Unit can be restarted using the following explicit message conforming to
DeviceNet communications.
Service 05 hex/Class 01 hex/Instance 01 hex/Attribute none/Data 00
Use this message to enable parameter settings that are reflected at restart such as the default con-
nection path and average power calculation cycle.
The Inverter will not restart from this command. To restart the Inverter, turn OFF the power and
then turn ON again.
10-2-2 Message Router Objects: Class 02 Hex
Message router objects have the function of distributing DeviceNet communications data. Message
router objects themselves are involved in internal processing only and do not have data to be
exchanged externally.
Support Service Code
Object Details
10-2-3 DeviceNet Objects: Class 03 Hex
DeviceNet objects are related to DeviceNet communications information and operations.
Processing is performed automatically after the communications connection is established, so the
functions and data have no particular use for the user.
Support Service Code
Service code number (hex) Service
0E Get attribute single
Instance Attribute Name Content Setting range Default Read Write Size
--- --- Not supported. --- --- --- --- --- ---
Service code number (hex) Service
0E Get attribute single
10 Set attribute single
4B Allocate Master/Slave Connec-
tion Set
4C Release Master/Slave Connec-
tion Set