Chapter 10
10-32
Appendices
● Status Signals: Register Number 0020 Hex
● Fault Status: Register Number 0021 Hex
00 35 0035 Accumulated operating
time
Read with 1 (h) = 1 decimal
00 36 0036 Not used. ---
00 37 0037 Output power Read with 1 (W) = 100 decimal
Read with +/
−.
00 38 0038 PID feedback Read with 1 (%) = 10 decimal
Maximum frequency corresponds to 100%.
00 39 0039 PID input Read with 1 (%) = 10 decimal
Maximum frequency corresponds to 100%.
Read with +/
−.
00 3A 003A PID output Read with 1 (%) = 10 decimal
Maximum frequency corresponds to 100%.
Read with +/
−.
00 3B 003B Output current Read with 1 (A) = 10 decimal Read with +/
−
00 3C 003C Not used. ---
00 3D 003D Communications error
content
Refer to the following Communications Error
Content table.
00 --- 003E to 00FF Not used. ---
Bit Content
0 During Run (1: During Run)
1 Forward/reverse operation (1: reverse operation)
2 Inverter ready (1: ready)
3 Fault (1: fault)
4 Data setting error (1: error)
5 Multi-function output 1 (1: ON)
6 Multi-function output 2 (1: ON)
7 Multi-function output 3 (1: ON)
8 to 15 Not used.
Bit Content
0OC
1OV
2OL2
3OH
4 Not used.
5 Not used.
6FBL
7EF@, STP
8F@
9OL1
10 OL3
Class 64 Register
number (hex)
Function Content
Instance Attribute