Chapter 1
1-9
Functions and System Configuration
Note Refer to 7-3 Edit Device Parameters Window for details on setting parameters with the Config-
urator.
refer to 5-5 Special Remote I/O Operation for details on setting parameters with special remote
I/O.
Refer to 6-7 Reading and Writing Parameters: Class 64 Hex for details on setting parameters
with message communications.
Refer to Chapter 10 Appendices for reference data such as register numbers, which are
required when setting parameters. The information is organized by Inverter series.
■ Comparison of Installation Specifications
The installation conditions for the 3G3MV-PDRT2 have changed in comparison to those for the
3G3MV-PDRT1-SINV(1). Observe the following precautions when changing models.
• Install the Unit into a metal panel.
The EMC immunity of the 3G3MV-PDRT2 is somewhat less than that of the 3G3MV-PDRT1-
SINV(1). Refer to 3-4 Conformity to EC Directives for information on electromagnetic wave coun-
termeasures.
• The installation dimension at the bottom has been increased by 7 mm.
Smart Slave
functions
Average Power Monitor Function Supported
(Advanced Func-
tion)
Not supported Chapter 7
Warning Torque Detection Function Supported
(Advanced Func-
tion)
Not supported
Current Trace Function Supported
(Advanced Func-
tion)
Not supported
Operating Time Monitor Function Supported
(Advanced Func-
tion)
Not supported
Cumulative ON Time Monitor Function Supported
(Advanced Func-
tion)
Not supported
Contact Operations Monitor Function Supported
(Advanced Func-
tion)
Not supported
Conduction Time Monitor Function Supported
(Advanced Func-
tion)
Not supported
Network Power Supply Voltage Monitor
Function
Supported Not supported
Unit Comment Function Supported Not supported
Connected Device Comment Function Supported Not supported
Communications Error Log Monitor
Function
Supported Not supported
Last Maintenance Date (Maintenance
Function)
Supported Not supported
Category Function New Unit/Card
(@-PDRT2)
Earlier Unit/Card
(@-PDRT1-SIN@)
Reference