Chapter 10
10-55
Appendices
■ Reference Parameters
Note Values exceeding the max. output frequency (E1-04 and E3-02) cannot be set. Set the motor
constant parameters first.
Con-
stant
Regis-
ter num-
ber
(hex)
Class 64 (hex) Name Setting
range
Setting
unit
Default
setting
Write
during
opera-
tion
In-
stance
At-
tribute
d1-01 0280 02 80 Frequency reference 1 0 to max.
output
fre-
quency
(See
note.)
0.01 Hz
(Set with
o1-03.)
0.00 Yes
d1-02 0281 02 81 Frequency reference 2 0.00 Yes
d1-03 0282 02 82 Frequency reference 3 0.00 Yes
d1-04 0283 02 83 Frequency reference 4 0.00 Yes
d1-05 0284 02 84 Frequency reference 5 0.00 Yes
d1-06 0285 02 85 Frequency reference 6 0.00 Yes
d1-07 0286 02 86 Frequency reference 7 0.00 Yes
d1-08 0287 02 87 Frequency reference 8 0.00 Yes
d1-09 0288 02 88 Frequency reference 9 0.00 Yes
d1-10 028B 02 8B Frequency reference 10 0.00 Yes
d1-11 028C 02 8C Frequency reference 11 0.00 Yes
d1-12 028D 02 8D Frequency reference 12 0.00 Yes
d1-13 028E 02 8E Frequency reference 13 0.00 Yes
d1-14 028F 02 8F Frequency reference 14 0.00 Yes
d1-15 0290 02 90 Frequency reference 15 0.00 Yes
d1-16 0291 02 91 Frequency reference 16 0.00 Yes
d1-17 0292 02 92 Jog frequency reference 6.00 Yes
d2-01 0289 02 89 Frequency reference upper limit 0.0 to
110.0
0.1% 100.0 No
d2-02 028A 02 8A Frequency reference lower limit 0.0 to
110.0
0.1% 0.0 No
d2-03 0293 02 93 Master speed reference lower limit 0.0 to
110.0
0.1% 0.0 No
d3-01 0294 02 94 Jump frequency 1 0.0 to
400.0
0.1 Hz 0.0 No
d3-02 0295 02 95 Jump frequency 2 0.1 Hz 0.0 No
d3-03 0296 02 96 Jump frequency 3 0.1 Hz 0.0 No
d3-04 0297 02 97 Jump frequency width 0.0 to
20.0
0.1 Hz 1.0 No
d4-01 0298 02 98 Frequency reference hold function
selection
0, 110No
d4-02 0299 02 99 + − Speed limits 0 to 100 1% 10 No
d6-01 02A0 02 A0 Field weakening level 0 to 100 1% 80 No
d6-02 02A1 02 A1 Field frequency 0.0 to
400.0
0.1 Hz 0.0 No