Chapter 1
1-8
Functions and System Configuration
1-3 Comparison to Earlier Models
The following table shows the functions that have been added to the DeviceNet Communications
Unit/Card (3G3MV-PDRT2 and 3G3RV-PDRT2), which are not available in the earlier DeviceNet
Communications Unit/Card (3G3MV-PDRT1-SIN
@ and 3G3FV-PDRT1-SIN@).
Refer to the Chapter in the “Reference” column for more details on each function.
Function Comparison Table
Category Function New Unit/Card
(@-PDRT2)
Earlier Unit/Card
(@-PDRT1-SIN@)
Reference
Remote I/O I/O allocation Basic I/O Supported Supported Chapter 5
Standard I/O Supported Supported
Advanced I/O Supported Supported
Control I/O Supported
(Advanced Func-
tion)
Supported
Unit Status Supported
(Advanced Func-
tion)
Not supported
Multi-function
Input Monitor
Supported
(Advanced Func-
tion)
Not supported
DeviceNet
Master con-
nectivity
Connection type Poll Supported Supported Chapter 5
Bit strobe Supported Not supported
Change of state Supported
(Advanced Func-
tion)
Not supported
Cyclic Supported Not supported
Connection path switching
(Selecting I/O allocation in Master’s
parameters)
Supported Supported
Default connection path switching
(Selecting the I/O allocation in the
Slave when power goes ON)
Supported
(Advanced Func-
tion)
Supported
Baud rate auto-detect
(Baud rate set automatically.)
Supported Not supported Chapter 7
Inverter Parameter settings Supported
(Advanced Func-
tion)
Supported See note.