Chapter 10
10-13
Appendices
Object Details
10-2-8 Motor Data Objects: Class 28 Hex
Motor data objects are data and functions related to motors connected to Inverters. The motors that
can be connected to Inverters are squirrel-cage inductive motors, so the “Motor Type” is always “7."
The motor's rated current and rated voltage can be set and read.
Support Service Code
Instance Attribute Name Content Setting range Default Read Write Size
00 01 Object Software
Revision
Indicates the software revi-
sion of Class 08.
The revision value increases
when changes have been
made.
--- 0001 Yes No Word
02 Max Instance Indicates the number of out-
put terminals. (Depends on
the Inverter being used.)
--- 0003 Yes No Word
01 to 03
(One per
terminal)
03 Value Terminal status
00: OFF, 01: ON
--- 00 Yes No Byte
05 Fault Action Hold/clear output after fault
00: Hold, 01: Clear
00, 01 00 Yes Yes Byte
65 Lifetime mode
selection
Maintenance count method
00: Conduction time,
01: Number of ON operations
00, 01 00 Yes Yes Byte
66 Lifetime present
value
Present value of the mainte-
nance count
--- 0000
0000
Ye s Ye s
Reset
Long
67 Lifetime monitor
flag
Maintenance count compari-
son result
(ON when PV threshold)
00: OFF, 01:ON
--- 00 Yes No Byte
68 Lifetime thresh-
old setting
Lifetime monitor value
Set the cumulative time that
the output is ON (s) or the
number of contact opera-
tions.
0000 0000 to
FFFF FFFF
0000
0000
Yes Yes Long
Service code number (hex) Service
0E Get attribute single
10 Set attribute single

Table of Contents