Chapter 10
10-25
Appendices
■ Object Details
● Operating Time Measurements (Measurement Patterns) of Instances 01 to 06
Note 1. The following table shows the meaning of “Input @” in a start or stop condition. When using
the control I/O remote I/O function, the input bit will be turned ON not only when the termi-
nal’s signal is ON, but also when the corresponding bit is turned ON from remote I/O. (The
terminal’s ON/OFF status is logically ORed with the status of the bit sent through remote I/
O.)
Instance Attribute Name Content Setting range Default Read Write Size
00 01 Object Software
Revision
Indicates the class 97
software revision. The
revision value is increased
whenever there is a
change.
--- 0001 Yes No Word
01 to 06
(See
note 1.)
65 OUTPUT
Response Time
Output response time
(ms)
--- 0000 Yes No Word
66 Response Time
exceed
Reports the result of the
comparison between the
monitor value and the
measured value. (ON
when output response
time > monitor value.)
00: OFF, 01: ON
--- 00 Yes Reset Byte
67 OUT response
monitor setting
Sets the output response
time monitor value (ms)
0000 to FFFF 0000 Yes Yes Word
68 Response peak
value
Peak value of the output
response time (ms)
--- 0000 Yes Reset Word
Instance Operating time measurement triggers Remarks
Measurement start condition Measurement
stop condition
Instance 01
(See note 2.)
Multi-function contact output = ON Input 4 = ON Output
→ Input
Instance 02
(See note 2.)
Multi-function output 1 = ON Input 5 = ON Output
→ Input
Instance 03 Input 2 = ON Input 3 = ON Input
→ Input
Instance 04 Input 4 = ON Input 5 = ON Input
→ Input
Instance 05 Input 0 = ON, input 1 = ON, or a run com-
mand is sent from the network
Input 4 = ON Forward or Reverse run
command
→ Input
Instance 06 Input 0 = ON, input 1 = ON, or a run com-
mand was sent from the network
Input 5 = ON Forward or Reverse run
command
→ Input
Name Meaning
3G3MV 3G3RV 3G3FV
Input 0 Status of terminal S1
(multi-function input 1)
Status of terminal S1 (Forward/
Stop)
Status of terminal 1 (For-
ward/Stop)
Input 1 Status of terminal S2
(multi-function input 2)
Status of terminal S2 (Reverse/
Stop)
Status of terminal 2
(Reverse/Stop)
Input 2 Status of terminal S3
(multi-function input 3)
Status of terminal S3 (multi-
function input 1 selection)
Status of terminal 3 (multi-
function contact input 1)
Input 3 Status of terminal S4
(multi-function input 4)
Status of terminal S4 (multi-
function input 2 selection)
Status of terminal 4 (multi-
function contact input 2)