4 - 41
4   Setting the Controller
Vision System FH/FHV/FZ5 Series User’s Manual (Z365)
4-6  Setting the Trigger Delay [Inter-camera Setting]
4
1 In the Main Window, select [System settings] − [Camera] − [Inter-camera setting] from the [Tool] 
menu. The Inter-camera Settings View is displayed.
2 Click a camera number to set the delay between STEP-cameras and then specify the delay 
count value.
 
Item
Set value
[Factory default]
Description
Delay count 
between STEP-
cameras
• FH series Sensor Controller:
-4 to 511
[0]
(1 count is 30 μs)
• FZ5 series Sensor Control-
ler:
0 to 511
[0]
(1 count is 30 μs)
Sets the delay time from when the STEP signal is received to 
when exposure begins for the selected Camera.
The delay time differs in FH series / FZ5 series.
• Delay time of FZ5 series Sensor Controller:
The time displayed for STEP-camera delay time is delay 
count between STEP-camera × 30 μs + 122 μs
• Delay time of FH series Sensor Controller:
When using cameras other than FH-S05R, the time dis-
played for STEP-camera delay time is (STEP-camera 
delay counts × 30 μs + 122 μs) + 120 μs.
When using the FH-S05R camera, the time displayed for 
STEP-camera delay time is (STEP-camera delay counts × 
30 μs + 122 μs) + 470 μs.
When using the FH-S21R camera, the time displayed for 
STEP-camera delay time is (STEP-camera delay counts × 
30 μs + 122 μs) + 1123 μs.
Transmission 
speed
[Standard] or High speed When you connect a camera that supports High speed mode 
using a camera cable shorter than 5m, image input time can 
be shortened by selecting [High speed] for frame rate.
For details about frame rate values, refer to the Instruction 
manual for the Camera.
The following cameras support [High speed]:
• FH-SC02/FH-SM02
• FH-SC04/FH-SM04
• FH-SC12/FH-SM12
• FH-SCX/FH-SMX
• FH-SCX05/FH-SMX05
• FH-SCX12/FH-SMX12
• FH-SC21R/FH-SM21R