10 Advanced Usage
10 - 10
Vision System FH/FHV/FZ5 Series Users Manual (Z365)
Precautions for Correct Use
If Ethernet cables are broken during the remote operation, Remote Operation Tool and the
Sensor Controller may be improperly operated.
After terminating the Remote Operation Tool return the Sensor Controller to the normal state
using Restart or Initialize buttons on the Remote Operation Tool.
If the Remote Operation Tool cannot be terminated with [End] in the file menu, terminate the
process of FZ-PanDA.exe from the task manager.
1 From the [Start] menu on your PC, select [All Programs] - [OMRON] - [FZ_FH Series] -
[FH_FHV Launcher].
FH/FHV Launcher window appears.
2 Click the [Remote Operation Tool] button.
3 In the [Version], select the version of the measurement application of the sensor controller to be
controlled remotely.
4 Click the [Run] button.
Note that the Sensor Controller must be placed in a measurement capable state.
Precautions for Correct Use
Do not connect or disconnect the [Remote Operation Tool] during a measurement or the sys-
tem running.
10-1-2 Connection Method for Remote Operation