EasyManua.ls Logo

Omron fh-1 series - Page 353

Omron fh-1 series
582 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 - 59
8 Setting Windows
Vision System FH/FHV/FZ5 Series Users Manual (Z365)
8-3 Arranging Windows [Layout Functions]
8
8-3-22 Value Input Window (MDI_NumBox.dll)
Important
Set subroutine name to specify in [Operation] in accordance with the following rules.
*+[Single-byte alphabetical character]+[Single-byte alphanumeric character and _ (under-
score)]
Example: *MEASUREDISP
In [Control], if using a macro RaiseOptionEvent to operate, then specify the control command
in the event number, and the control parameters in the parameter.
Upper limit
(Ident/Number)
Lower limit
(Ident/Number)
[Blank] Sets the upper limit/lower limit numerical values that can be
input using up to 32 characters.
The setting contents vary depending on [Data type].
Unit data: External reference data
number or identifier name
Scene variable or System variable: Variable name
System data or Global data: Identifier name
Decimal digits 0 to 10 [0] Sets the number of digits after the decimal point for the data to
input numerical value.
Status Sets the window part status.
Front/Back [Blank] Specifies the variable to store the status of the numerical value
input window from the variable allocation window.
However, only scene variables and system variables can be
specified.
Refer to Assigning variables on page 5-61.
When the variable value is:
Positive: Move the window to the front.
Negative: Move the window to the back.
0: Do not move the window.
Operation Sets this when calling a macro subroutine after inputting
numerical values and updating data.
Macro subroutine
after edit
[Blank] This is effective only when [Unit data] is selected in [Data type]
and a macro is specified in [Unit].
Control Sets this when changing the status of the numerical value input
window using a macro.
Control ID 0 to 999 [0] The ID used to identify the operation object if using the macro
RaiseOptionEvent relationship to carry out operations.
Setting item
Setting value
[Factory default]
Description

Table of Contents

Related product manuals