App-13
Appendix-1 Parameter List
Others
b086
Frequency 
conversion 
coefficient
0.1 to 99.9 1.0 Yes ⎯
b087
STOP key 
selection
00: Enabled
01: Disabled
00 No ⎯
b088
Free-run stop 
selection
00: 0 Hz start
01: Active Frequency Matching restart
00 No ⎯
b089
Monitor display 
selection
01: Output frequency monitor
02: Output current monitor
03: Rotation direction monitor
04: PID feedback value monitor
05: Multi-function input monitor
06: Multi-function output monitor
07: Frequency conversion monitor
01 Yes ⎯
b091 Stop selection
00: Deceleration → Stop
01: Free-run stop
00 No ⎯
b092 Cooling fan control
00: Always ON
01: ON during RUN
02: Depends on the fin temperature
01 No ⎯
b130
Overvoltage LAD 
stop function
00: Disabled
01: Enabled
00 No ⎯
b131
Overvoltage LAD 
stop function level 
setting
200-V class: 330. to 395.
400-V class: 660. to 790.
380/
760
Yes V
b133
Overvoltage 
protection function 
selection during 
deceleration
00: Disabled
01: Enabled
00 No ⎯
b134
Overvoltage 
protection level 
setting during 
deceleration
200-V class: 330. to 395.
400-V class: 660. to 790.
380/
760
No V
b140
Overcurrent 
suppression 
function
00: Disabled
01: Enabled
01 No ⎯
b150
Automatic carrier 
reduction
00: Disabled
01: Enabled
00 No ⎯
b151
Ready function 
selection
00: Disabled
01: Enabled
00 No ⎯
Parameter 
No.
Function name
Monitor or data range
(Digital Operator)
Default 
setting
Changes 
during 
operation
Unit
Set 
value
* 2nd control is displayed when SET (08) is allocated to one of from C001 to C005.