Remove SAS Storage Drive Cables
b.
Extend the server to the maintenance position.
See “Extend the Server to the Maintenance Position” on page 55.
c.
Attach an antistatic wrist strap to your wrist, and the to a metal area on the
chassis.
See “Electrostatic Discharge Safety” on page 48.
d.
Remove the server top cover.
See “Remove the Server Top Cover” on page 58.
e.
Remove fan modules.
See “Remove a Fan Module” on page 67.
f.
Swivel the air baffle into the upright position to allow access to the SAS
storage drive cables.
g.
Remove the server's front fan assembly door cover.
See “Remove the Fan Assembly Door From the Server” on page 59.
2.
Disconnect the SAS cables.
a.
To disconnect the SAS cables between the Oracle Storage 12 Gb/s SAS
PCIe RAID HBA card in PCIe slot 6 and the front storage drive backplane,
press each latch, and then pull out to disengage the cable from each SAS
connector [1 and 2].
See also “Remove the Sun Storage 12 Gb/s SAS PCIe RAID HBA Card” on page 124.