Monitoring System Components
■
“System Board Components” on page 237
■
“System Firmware Components” on page 239
■
“Hard Disk Drive Components” on page 239
Processor Components
The following table lists the processor (CPU) components.
Component Name (Oracle
ILOM CLI Targets)
IPMI Type Description Values (if applicable)
/SYS/MB/P[0-x] FRU Host CPU FRU
/SYS/MB/P[0-x]/PRSNT Discrete
sensor
Host CPU is present. 01h-ENTITY_PRESENT
02h-ENTITY_ABSENT
/SYS/MB/P[0-x]/SERVICE Indicator Host CPU Service
Required LED
Color: Amber
Location: Mainboard
Off: Normal
On: Processor was diagnosed as
faulty.
/SYS/MB/P[0-x]/V_DIMM Static sensor CPU DIMM bank
operating voltage
1.2V
Related Information
■
“System Chassis Components” on page 231
■
“Cooling Unit Components” on page 233
■
“Disk Backplane Components” on page 234
■
“Memory Device Components” on page 235
■
“Power Unit Components” on page 236
■
“System Board Components” on page 237
■
“System Firmware Components” on page 239
■
“Hard Disk Drive Components” on page 239
System Board Components
The following table lists the system board components.
Monitoring Components and Identifying SNMP Messages 237