Memory Events
Messages and Descriptions Component Name
Severity and Description: Informational; A fan speed sensor has reported that its value has gone
below an upper critical threshold setting or above a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapFanSpeedFatalThresholdExceeded
Oracle ILOM Event Message: Lower fatal threshold exceeded
Severity and Description: Critical; A fan speed sensor has reported that its value has gone above
an upper fatal threshold setting or below a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/MB/FM[0-3]/F[0-1]/TACH
SNMP Trap: sunHwTrapFanSpeedFatalThresholdDeasserted
Oracle ILOM Event Message: Lower fatal threshold no longer exceeded
Severity and Description: Informational; A fan speed sensor has reported that its value has gone
below an upper fatal threshold setting or above a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/MB/FM[0-3]/F[0-1]/TACH
Related Information
“System Chassis Components” on page 231
“Cooling Unit Components” on page 233
“Disk Backplane Components” on page 234
“Memory Device Components” on page 235
“Power Unit Components” on page 236
“Processor Components” on page 237
“System Board Components” on page 237
“Hard Disk Drive Components” on page 239
Memory Events
The following table lists memory events.
Messages and Descriptions Component Name
SNMP Trap: sunHwTrapSensorNonCritThresholdExceeded /SYS/VPS_CPUS
Monitoring Components and Identifying SNMP Messages 249