Memory Events
Messages and Descriptions Component Name
Oracle ILOM Event Message: Upper noncritical threshold exceeded
Severity and Description: Minor; A sensor has reported that its value has gone above an upper
non critical threshold setting or below a lower non critical threshold setting. This generic 'sensor'
trap is generated when the SNMP agent does not recognize the component type.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower.
/SYS/VPS_MEMORY
SNMP Trap: sunHwTrapSensorThresholdOk
Oracle ILOM Event Message: Upper noncritical threshold no longer exceeded
Severity and Description: Informational; A sensor has reported that its value is in the normal
operating range. This generic 'sensor' trap is generated when the SNMP agent does not recognize
the component type.
/SYS/VPS_CPUS
/SYS/VPS_MEMORY
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.cpu.intel.quickpath.link_slow "The Quickpath
Interconnect (QPI) link is operating below normal speed."
Severity and Description: Major; A memory component is suspected of causing a fault.
/SYS/MB
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.cpu.intel.quickpath.link_slow "The Quickpath
Interconnect (QPI) link is operating below normal speed."
Severity and Description: Informational; A memory component fault has been cleared.
/SYS/MB
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.cpu.intel.quickpath.unknown-errcode "An unknown
error code from the Quickpath Interconnect (QPI) reference code has been detected."
Severity and Description: Major; A memory component is suspected of causing a fault.
/SYS/MB
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.cpu.intel.quickpath.unknown-errcode "An unknown
error code from the Quickpath Interconnect (QPI) reference code has been detected."
Severity and Description: Informational; A memory component fault has been cleared.
/SYS/MB
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.none "An invalid memory DIMM
configuration has been detected."
Severity and Description: Major; A memory component is suspected of causing a fault.
/SYS/MB
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.none "An invalid memory DIMM
configuration has been detected."
Severity and Description: Informational; A memory component fault has been cleared.
/SYS/MB
SNMP Trap: sunHwTrapMemoryFault /SYS/MB
250 Oracle Exadata Storage Server X5-2 High Capacity Service Manual • January 2018