Memory Events
Messages and Descriptions Component Name
Oracle ILOM Event Message: event fault.memory.intel.dimm.memtest-failed "All memory
channels have been disabled due to memory test failures."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.memtest-failed "All memory
channels have been disabled due to memory test failures."
Severity and Description: Informational; A memory component fault has been cleared.
/SYS/MB
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.quadrank-3rd-slot "A quad-rank
memory DIMM has been installed in the third slot of a memory channel."
Severity and Description: Major; A memory component is suspected of causing a fault.
/SYS/MB
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.quadrank-3rd-slot "A quad-rank
memory DIMM has been installed in the third slot of a memory channel."
Severity and Description: Informational; A memory component fault has been cleared.
/SYS/MB
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.ddr3u-unsupported "An
unsupported DDR3 ultra low voltage memory DIMM has been detected."
Severity and Description: Major; A memory component is suspected of causing a fault.
/SYS/MB
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message:event fault.memory.intel.dimm.ddr3u-unsupported "An
unsupported DDR3 ultra low voltage memory DIMM has been detected."
Severity and Description: Informational; A memory component fault has been cleared.
/SYS/MB
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.mrc.unknown-errcode "An unknown
error code from the Memory Reference Code (MRC) has been detected."
Severity and Description: Major; A memory component is suspected of causing a fault.
/SYS/MB
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.mrc.unknown-errcode "An unknown
error code from the Memory Reference Code (MRC) has been detected."
Severity and Description: Informational; A memory component fault has been cleared.
/SYS/MB
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.udimm-unsupported "An
unbuffered memory DIMM (UDIMM) has been detected."
Severity and Description: Major; A memory component is suspected of causing a fault.
/SYS/MB/P[0-x]/D[0-11]