EasyManua.ls Logo

Oracle EXADATA X5-2 - Page 247

Oracle EXADATA X5-2
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power Events
Messages and Descriptions Component Name
Severity and Description: Major; A power supply sensor has reported that its value has gone
above an upper critical threshold setting or below a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
SNMP Trap: sunHwTrapSensorCritThresholdDeasserted
Oracle ILOM Event Message:Lower critical threshold no longer exceeded
Severity and Description: Informational; A power supply sensor has reported that its value has
gone below an upper critical threshold setting or above a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
SNMP Trap: sunHwTrapVoltageFatalThresholdExceeded
Oracle ILOM Event Message: Lower fatal threshold exceeded
Severity and Description: Critical; A voltage sensor has reported that its value has gone above
an upper fatal threshold setting or below a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/MB/P[0-x]/V_DIMM
SNMP Trap: sunHwTrapVoltageFatalThresholdDeasserted
Oracle ILOM Event Message: Lower fatal threshold no longer exceeded
Severity and Description: Informational; A voltage sensor has reported that its value has gone
below an upper fatal threshold setting or above a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/MB/P[0-x]/V_DIMM
SNMP Trap: sunHwTrapVoltageCritThresholdExceeded
Oracle ILOM Event Message: Upper critical threshold exceeded
Severity and Description: Critical; A voltage sensor has reported that its value has gone above
an upper critical threshold setting or below a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/MB/P[0-x]/V_DIMM
SNMP Trap: sunHwTrapVoltageCritThresholdDeasserted
Oracle ILOM Event Message: Upper critical threshold no longer exceeded
Severity and Description: Informational; A voltage sensor has reported that its value has gone
below an upper critical threshold setting or above a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
/SYS/MB/P[0-x]/V_DIMM
SNMP Trap: sunHwTrapVoltageNonCritThresholdExceeded
Oracle ILOM Event Message: Upper noncritical threshold exceeded
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
Monitoring Components and Identifying SNMP Messages 247