Troubleshoot Hardware Faults Using the Oracle ILOM Web Interface
The Memory screen appears.
The above example shows the Memory subsystem screen and indicates that DIMM 8 on CPU 0
has an uncorrectable ECC fault.
6.
To get more information, click one of the Open Problems links.
The Open Problems screen provides detailed information, such as the time the event occurred,
the component and subsystem name, and a description of the issue. It also includes a link to an
Oracle KnowledgeBase article.
Tip - The System Log provides a chronological list of all the system events and faults that have
occurred since the log was last reset and includes additional information, such as severity levels
and error counts. The System Log also includes information on devices not reported in the
Subsystem Summary screen. To access the System Log, click the System Log link.
In this example, the hardware fault with DIMM 8 of CPU 0 requires local/physical access to the
server.
7.
To prepare the server for service, see “Preparing for Service” on page 47.
After servicing the component, you might need to clear the fault in Oracle ILOM. For more
information, refer the service procedure for the component.
8.
Service the component.
Troubleshooting and Diagnostics 25