Error
98 I11 T11 192-120101 N6 - March 2004
Error code (hex):
0xFF03
Error:
Object is "read only"
Error reaction:
None
Measure:
Note:
No write access
Error code (hex):
0xFF04
Error:
Object cannot be read
Error reaction:
None
Measure:
Note:
No read access
Error code (hex):
0xFF05
Error:
Version conflict; object data not valid in flash
Error reaction:
None
Measure:
Note:
Internal error
Error code (hex):
0xFF06
Error:
No object for process data; object cannot be mapped
Error reaction:
None
Measure:
Note:
This object cannot be mapped on the cyclic data
Error code (hex):
0xFF07
Error:
Data not valid
Error reaction:
None
Measure:
Note:
No OPM text present
Error code (hex):
0xFF08
Error:
No convert function
Error reaction:
None
Measure:
Note:
Internal error
Error code (hex):
0xFF10
Error:
Command syntax error
Error reaction:
None
Measure:
Note:
Syntax error
Error code (hex):
0xFF11
Error:
Value not valid
Error reaction:
None
Measure:
Note:
Argument incorrect
Error code (hex):
0xFF12
Error:
Checksum error
Error reaction:
None
Measure:
Note:
Checksum CRC incorrect
Error code (hex):
0xFF13
Error:
Timeout error
Error reaction:
None
Measure:
Note:
Active in binary protocol; 5 ms
Error code (hex):
0xFF14
Error:
Overflow error
Error reaction:
None
Measure:
0xFF03
0xFF04
0xFF05
0xFF06
0xFF07
0xFF08
0xFF10
0xFF11
0xFF12
0xFF13
0xFF14

Table of Contents

Other manuals for Parker Compax3 S150 V4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Compax3 S150 V4 and is the answer not in the manual?

Parker Compax3 S150 V4 Specifications

General IconGeneral
Output Current150 A
Control TypeDigital
SeriesCompax3
ModelS150 V4
Enclosure RatingIP20
Communication InterfacesCANopen, RS-232, RS-485
Feedback OptionsResolver
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Relative Humidity5 to 95% non-condensing
Operating Temperature0 to +45 °C (32 to 113 °F)