EasyManuals Logo

Parker Compax3 S150 V4 User Manual

Parker Compax3 S150 V4
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #99 background imageLoading...
Page #99 background image
Parker EME
Error
I11 T11 192-120101 N6 - March 2004 99
Note:
Utype error
Error code (hex):
0xFF15
Error:
Parity error
Error reaction:
None
Measure:
Note:
Utype error
Error code (hex):
0xFF16
Error:
Frame error
Error reaction:
None
Measure:
Note:
Utype error
Error code (hex):
0xFF20
Error:
Flash sector delete failed
Error reaction:
None
Measure:
Note:
Error while deleting flash
Error code (hex):
0xFF21
Error:
Program flash cell failed
Error reaction:
None
Measure:
Note:
Error while programming flash
Error code (hex):
0xFF22
Error:
Checksum error of prog. Flash area
Error reaction:
None
Measure:
Note:
Error for flash checksum
Error code (hex):
0xFF23
Error:
DOWN/UPLOAD activated
Error reaction:
None
Measure:
Note:
Download or upload is active
Error code (hex):
0xFF24
Error:
DOWN/UPLOAD not activated
Error reaction:
None
Measure:
Note:
Download or upload is inactive
Error code (hex):
0xFF30
Error:
EEPROM Delay Count Error
Error reaction:
None
Measure:
Note:
Internal error
Error code (hex):
0xFF40
Error:
Not enough memory for OSZI or AWL reserved
Error reaction:
None
Measure:
Note:
An attempt was made to reserve too much memory (IEC, osci)
Error code (hex):
0xFF42
Error:
No objects available
Error reaction:
None
Measure:
Load application data into device (objects)
Note:
Application data error; no valid objects present
LED red flashing
Error code (hex):
0xFF43
Error:
No IEC61131 program
0xFF15
0xFF16
0xFF20
0xFF21
0xFF22
0xFF23
0xFF24
0xFF30
0xFF40
0xFF42
0xFF43

Table of Contents

Other manuals for Parker Compax3 S150 V4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Compax3 S150 V4 and is the answer not in the manual?

Parker Compax3 S150 V4 Specifications

General IconGeneral
Output Current150 A
Control TypeDigital
SeriesCompax3
ModelS150 V4
Enclosure RatingIP20
Communication InterfacesCANopen, RS-232, RS-485
Feedback OptionsResolver
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Relative Humidity5 to 95% non-condensing
Operating Temperature0 to +45 °C (32 to 113 °F)