15
Forming the capacitors
Forming the capacitors only required with 400VAC axis controllers and PSUP
mains module
If the device was stored longer than one year, the intermediate capacitors must be
re-formed!
Forming sequence:
Remove all electric connections
Supply the device with 230VAC single phase for 30 minutes
via the L1 and L2 terminals on the device or
multi axis devices via L1 and L2 on the PSUP mains module
Please note in the
event of storage >1
year:

Table of Contents

Other manuals for Parker Compax3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Compax3 and is the answer not in the manual?

Parker Compax3 Specifications

General IconGeneral
Protection ClassIP20
Control ModesTorque, Speed, Position
Feedback OptionsIncremental encoder, Absolute encoder, Resolver
Communication InterfacesCANopen, EtherCAT, Profinet
Safety FeaturesSTO (Safe Torque Off), SS1 (Safe Stop 1), SOS (Safe Operating Stop)
Input Voltage200-480 VAC
Relative Humidity5% to 85% (non-condensing)
Shock ResistanceAccording to EN 60068-2-27
Operating Temperature0°C to +40°C