Setting up Compax3
C3I12T11
188
192-120113 N08 C3I12T11 - December 2010
Motor types supported
Compax3 supports the following motor types:
Permanently excited synchronous rotary motors
Permanently excited synchronous linear motors
Asynchronous rotary motors
In general, rotary and linear motors do have the same signal flow chart. The
difference consists solely in the basic physical values, which refer to circular
movement resp. the linear motion laws of physics. For this, the following analogies
can be established:
Rotary drive [unit] Linear drive [unit]
Travel x [rev] Path x [m]
Mass moment of inertia J [kgm²] Mass m [kg]
Velocity n
Angular velocity ω
[rps]
[1/s]
Velocity v [m/s]
Torque constant Kt [Nm/Arms] Force constant KF [N/Arms]
Torque M [Nm] Force F [N]
For reasons of clarity, we will in the following refer to the rotary motor, which
will represent both drive types.
An asynchronous motor is set up in the same way as a synchronous motor. The
only differences are varying motor parameters.
Changing the switching frequency and the reference point
The switching frequency and the reference point are activated in the
ServoManager: "Motor reference point" wizard
A reference point differing from the nominal data may also be entered on the
wizard page displayed above.
Please activate "activate changing the reference point", then you may enter the
new reference velocity as well as the new reference current.
Motor reference point
A reference point differing from the nominal data may also be entered on the
wizard page displayed above.
Please activate "activate changing the reference point", then you may enter the
new reference velocity as well as the new reference current.
External Moment of Inertia
The external mass moment of inertia is set against the moment of inertia of the
rotor to form the total moment of inertia. The total moment of inertia is used for the
controller design.
If you do not know or have only a vague knowledge of the external mass moment
of inertia, the mass inertia can be determined via the load identification.
Configuration of an unknown external mass inertia:
The load identification is activated in the ServoManager:
Wizard "External moment of inertia" “unknown: Using default values”.
The correct values can be determined later via the load identification!

Table of Contents

Other manuals for Parker Compax3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Compax3 and is the answer not in the manual?

Parker Compax3 Specifications

General IconGeneral
Protection ClassIP20
Control ModesTorque, Speed, Position
Feedback OptionsIncremental encoder, Absolute encoder, Resolver
Communication InterfacesCANopen, EtherCAT, Profinet
Safety FeaturesSTO (Safe Torque Off), SS1 (Safe Stop 1), SOS (Safe Operating Stop)
Input Voltage200-480 VAC
Relative Humidity5% to 85% (non-condensing)
Shock ResistanceAccording to EN 60068-2-27
Operating Temperature0°C to +40°C