Compax3 device description
192-120113 N08 C3I12T11 - December 2010
83
Note on error switch-off
If the "safe torque off" function of Compax3 is required or used for
a machine or system, the two errors:
“Motor_Stalled” (Motor stalled) and
“Tracking” (following error)
are
not to be switched off (see on page 133, see on page 151).
Note on RS485 implementation: The “Energize” function (channel 1) can be
implemented via the RS485 bus interface (X10) via a corresponding programming
of the Compax3.
If, in this case, the motor current is to be disabled via channel 1, the Bit0 of the
DeviceControl (Control word_1) must be set to LOW” via the RS485 bus interface.