THE NEW PIPER AIRCRAFT, INC.
PA-32-301FT / 301XTC
MAINTENANCE MANUAL
PAGE 7
Jun 1/03
3I21
35-10-00
Oxygen System Test Apparatus
Figure 3
CHART 3
FIXED OXYGEN SYSTEM COMPONENT LIMITS
Component Inspection Overhaul
Cylinder Weekly
1
Each 3 Years
Regulator On Condition / Each Use
2
Each 6 Years
Pressure Gauge On Condition / Each Use
2
Replace On Condition
High Pressure Lines On Condition / Each Use
2
Replace On Condition
Low Pressure Lines On Condition / Each Use
2
Replace On Condition
Outlets On Condition / Each Use
2
Each 5 Years
3
External Recharge Valve On Condition / Each Use
2
Replace On Condition
4
Masks On Condition / Each Use
2
Each 5 Years
1. Visual inspection for dents, bulges, corrosion, or chafing.
2. Visual inspection in the normal course of use.
3. On condition, replace the rubber components in the assembly or replace assembly.
4. If the screen in front of valve is dirty, replace valve. Valve replacement is recommended every 5 years.