WinLink 1000 User Manual Release 1.9.40 B-1
Appendix B
Wiring Specifications
ODU-IDU Cable
The ODU-IDU cable is shielded/outdoor class CAT-5e, 4 twisted-pair 24 AWG terminated with
RJ-45 connectors on both ends. A cable gland on the ODU side provides hermetic sealing.
The following table shows the connector pinout:
ODU/HSS Unit Connection Pinout
Table B-1: ODU-IDU RJ-45 Connector Pinout
Function Color IDU ODU
Ethernet (RxN) White/Green 1 1
Ethernet (RxT) Green 2 2
Ethernet (TxT) White/Orange 3 3
Ethernet (TxN) Orange 6 6
Power (+) Blue 4 4
Power (+) White/Blue 5 5
Power () White/Brown 7 7
Power () Brown 8 8
Table B-2: ODU/HSS Unit Connection Pinout
Color
ODU
RJ-45
HSS UNIT
RJ-45
White/Green 1 1
Green
Not connected
White/Orange
Orange 6 6
Blue 4 4
White/Blue 5 5