EasyManua.ls Logo

Radwin WinLink 1000 - Table 1-2 Win Link 1000 F

Radwin WinLink 1000
348 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The Outdoor Unit (ODU) Chapter 1
WinLink 1000 User Manual Release 1.9.40 1-8
The WinLink 1000 ODUs come is many variations reflecting supported combinations of regu-
lations and frequency bands as shown in Table 1-2
:
Key to abbreviations:
FCC - Federal Communications Commission
IC - Canadian radio regulation
ETSI - European Telecommunications Standards Institute
IDA - Indian WPC radio regulation
CN - China MII radio regulation
UK - Office of Communications - Radio Interface Requirement
HP - no specific radio regulation
Supported IDU
devices
PoE PoE PoE PoE and IDU PoE and IDU
Services Ethernet Ethernet Ethernet Ethernet and TDM
Ethernet and
TDM
HSS Yes Yes Yes No Yes
Tx Power 18dBm 18dBm 18dBm 18dBm 25dBm
Table 1-2: WinLink 1000 Frequency Bands And Radio Regulations
FCC/IC ETSI
IDA
(WPC India)
CN
(MII China)
UK
HP
(Universal)
2.3 GHz 2.302 - 2.397
2.4 GHz 2.402 - 2.472 2.402 - 2.482 2.312 - 2.482
2.5 GHz 2.496 - 2.690
2.7 GHz 2.700 - 2.900
4.9 GHz 4.940 - 4.990 4.940 - 4.990
5.3 GHz 5.250 - 5.350 5.170 - 5.330 5.140 - 5.345
5.4 GHz
FCC:
5.475 - 5.720
IC:
5.475 – 5.595
5.655 - 5.720
5.490 - 5.710 5.475 - 5.720
5.7 GHz 5.690 – 5.880
5.8 GHz 5.730 - 5.845 5.725 - 5.875 5.825 - 5.875 5.730 - 5.845 5.725 - 5.845 5.720 – 5.880
5.9 GHz 5.730 - 5.950
6.0 GHz 5.795 - 6.030
Table 1-1: ODU Series Typical Characteristics (Continued)
WinLink 1000
Access
WinLink 1000
Access Pro
WinLink 1000
VS
WinLink 1000
WinLink 1000
High End

Table of Contents