Protection against Lightning Chapter 3
WinLink 1000 User Manual Release 1.9.40 3-2
outdoor unit, mast, lead-in wire and discharge unit. It also lays down the size of
grounding conductors and connection requirements for grounding electrodes.
The WinLink 1000 ODU must be grounded to a Protective Earth as described in
Chapter 18 and in accordance with the Local Electrical Regulations.
The earth lug on the IDU-C should be connected to the protective earth at all times,
by a wire with a diameter of 18 AWG or wider. Rack-mounted equipment should be
mounted only in earthed racks and cabinets.
Further, you should -
Always make the ground connection first and disconnect it last
Never connect telecommunication cables to ungrounded equipment
Ensure that all other cables are disconnected before disconnecting the ground
More detailed guidelines are supplied in Chapter 18.
Protection against Lightning
The use of lightning protection is dependent on regulatory and end user requirements. All of
RADWIN outdoor units are designed with surge limiting circuits to minimize the risk of dam-
age due to lightning strikes. RADWIN recommends the use of additional surge arrestor
devices to protect the equipment from nearby lightning strikes.
See Chapter 18 for detailed installation instructions of lightning protection devices.
General
It is recommended that installation of the outdoor unit be contracted to a professional
installer.
Before working on equipment connected to power lines or telecommunication lines,
you should remove jewelry or any other metallic object that may come into contact
with energized parts.
Use extreme care when installing antennas near power lines.
Use extreme care when working at heights.
When using an AC power source for WinLink 1000 always use the AC power adapter
supplied by RADWIN.
Use the right tools. In addition to standard tools required for any kind of ODU or
antenna installation, WinLink 1000 requires additional specific tools detailed on
page 3-6 below.
Package Contents
The WinLink 1000 packages include the following items:
ODU Package Contents
The ODU package contains:
One ODU - see Figure 3-2 and Figure 3-3 below for front and rear view
An ODU mounting kit - see Figure 3-1 below
A CD containing -

Table of Contents

Other manuals for Radwin WinLink 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin WinLink 1000 and is the answer not in the manual?

Radwin WinLink 1000 Specifications

General IconGeneral
BrandRadwin
ModelWinLink 1000
CategoryWireless Access Point
LanguageEnglish

Related product manuals