The RADWIN Manager log-on Concept Chapter 4
WinLink 1000 User Manual Release 1.9.40 4-5
Figure 4-5: Log on window exposing the user types.
There are three user types:
• An Observer has read-only access to the link. An Observer can monitor the link, gen-
erate reports, but may not change any link parameters.
• An Operator can install and configure the link.
• An Installer can, in addition to functioning as an Operator, also change the operating
band. The latter function has legal ramifications, requiring familiarity with local regula-
tions.
The following table summarizes these options:
The Network Manager should change the default passwords as soon as possible.
Continuing the log-on procedure:
5. Type an IP address for the ODU (if you connect through a LAN), or click Local Con-
nection (if you are connected directly to the IDU port).
Table 4-2: User types, default passwords and function
User Type
Default
Password
Function Community
Community
String
Observer admin Monitoring Read-Only public
Operator admin
Installation,
configuration
Read-Write netman
Installer wireless
Operator plus
set band
Read-Write netman