MIB Parameters Appendix D
WinLink 1000 User Manual Release 1.9.40 D-17
winlink1000OduPerfMonEthDayTxMBytes RO Current Transmit Mega Bytes per day.
winlink1000OduPerfMonEthDayEthCapacityTh
reshUnder
RO The number of times throughput was below
threshold each day.
winlink1000OduPerfMonEthDayHighTrafficThr
eshExceed
RO The number of times actual traffic was above
threshold each day.
winlink1000OduPerfMonEthDayActiveSeconds RO The number of seconds in which RPL Ethernet
service was not blocked each day.
winlink1000OduPerfMonTdmCurrTable N/A This table defines/keeps the TDM counters of the
current 15 min interval.
winlink1000OduPerfMonTdmCurrEntry N/A This is an entry in the Current Interval Table.
INDEX {ifIndex }
winlink1000OduPerfMonTdmCurrActiveSecon
ds
1.3.6.1.4.1.4458.1000.1.6.10.1.1 Gauge RO Parameter indicating whether the TDM service
was active. Under TDM backup link the
parameter indicates whether the backup link
was active.
winlink1000OduPerfMonTdmIntervalTable N/A This table defines/keeps the TDM counters of the
last day (in resolution of 15 min intervals).
winlink1000OduPerfMonTdmIntervalEntry N/A This is an entry in the Interval Table. INDEX
{ifIndex winlink1000OduPerfMonTdmIntervalIdx }
winlink1000OduPerfMonTdmIntervalIdx RO This table is indexed per interval number. Each
interval is of 15 minutes and the oldest is 96.
winlink1000OduPerfMonTdmIntervalActiveSec
onds
RO Parameter indicating whether the TDM service
was active. Under TDM backup link the
parameter indicates whether the backup link was
active.
winlink1000OduPerfMonTdmDayTable N/A This table defines/keeps the TDM counters of the
last month (in resolution of days).
winlink1000OduPerfMonTdmDayEntry N/A This is an entry in the Days Table. INDEX {ifIndex
winlink1000OduPerfMonTdmDayIdx }
winlink1000OduPerfMonTdmDayIdx RO This table is indexed per Day number. Each
interval is of 15 minutes and the oldest is 96.
winlink1000OduPerfMonTdmDayActiveSecond
s
RO Parameter indicating whether the TDM service
was active. Under TDM backup link the
parameter indicates whether the backup link was
active.
winlink1000OduPerfMonTxThresh1 1.3.6.1.4.1.4458.1000.1.6.20 Integer RW When the Transmit power exceeds this threshold
a performance monitoring TSL1 counter is
incremented.
winlink1000OduPerfMonRxThresh1 1.3.6.1.4.1.4458.1000.1.6.21 Integer RW When the RX power exceeds this threshold a
performance monitoring RSL1 counter is
incremented.
winlink1000OduPerfMonRxThresh2 1.3.6.1.4.1.4458.1000.1.6.22 Integer RW When the RX power exceeds this threshold a
performance monitoring RSL2 counter is
incremented.
winlink1000OduPerfMonBBERThresh1 1.3.6.1.4.1.4458.1000.1.6.23 Integer RW When the BBER exceeds this threshold a
performance monitoring BBER counter is
incremented. The units are 1/10 of a percent.
winlink1000OduPerfMonEthCapacityThreshKb
ps
1.3.6.1.4.1.4458.1000.1.6.24 Integer RW When the current throughput is below this
threshold the corresponding counter is
incremented
winlink1000OduPerfMonHighTrafficThreshKbp
s
1.3.6.1.4.1.4458.1000.1.6.25 Integer RW When the current traffic is above this threshold
then corresponding counter is incremented.
winlink1000OduAgnGenAddTrapExt 1.3.6.1.4.1.4458.1000.1.7.1.1 Integer RW If 'yes' is chosen the ifIndex Unit Severity
Time_T and Alarm Id from the
winlink1000OduAgnCurrAlarmTable will be bind
to the end of each private trap.
Table D-2: Private MIB Parameters (Sheet 12 of 18)
Name OID Type
Access
Description