Remote Commands Reference
R&S
®
RTC1000
306User Manual 1335.7352.02 ─ 02
BUS<b>:CAN:FRAMe<n>:CSValue?
Returns the checksum value.
Suffix:
<b>
.
1, 2
Selects the bus.
<n> Selects the frame (1...n).
Return values:
<ChecksumValue> Decimal value
Usage: Query only
BUS<b>:CAN:FRAMe<n>:DLCValue?
Returns the value of the data length code field of a frame.
Suffix:
<b>
.
1, 2
Selects the bus.
<n> Selects the frame (1...n).
Return values:
<DLCValue> Non-negative integer
Usage: Query only
BUS<b>:CAN:FRAMe<n>:IDTYpe?
Returns the length of the identifier: 11 bit for CAN base frames, or 29 bits for CAN
extended frames.
Suffix:
<b>
.
1, 2
Selects the bus.
<n> Selects the frame (1...n).
Return values:
<IdentifierType> B11 | B29
B11
Identifier type is 11 bit
B29
Identifier type is 29 bit
Usage: Query only
BUS<b>:CAN:FRAMe<n>:IDValue?
Returns the decimal address value of the specified frame.