EasyManua.ls Logo

R&S RTC1000 - Bus<B>:Lin:frame<N>:Start; Bus<B>:Lin:frame<N>:Stop

R&S RTC1000
371 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Commands Reference
R&S
®
RTC1000
314User Manual 1335.7352.02 ─ 02
Return values:
<FrameStatus> OK | CHKS | WAKeup | SYER | INS | ERR | UNDF | IPER
OK
Frame is valid.
CHKS
Checksum error occured.
WAKeup
Wake up occured.
SYER
Synchronisation
INS
Identifier is insufficient.
ERR
Error
UNDF
Undefined
IPER
ID parity error
Usage:
Query only
BUS<b>:LIN:FRAMe<n>:STARt?
Returns the start time of the specified frame.
Suffix:
<b>
.
1, 2
Selects the bus.
<n> Selects the frame (1...n).
Return values:
<StartTime> Range: depends on sample rate, and time base
Default unit: s
Usage: Query only
BUS<b>:LIN:FRAMe<n>:STOP?
Returns the end time of the specified frame.
Suffix:
<b>
.
1, 2
Selects the bus.
<n> Selects the frame (1...n).
Return values:
<StopTime> Range: depends on sample rate, and time base
Default unit: s
Protocol Analysis