Rexroth EcoDrive Cs Drives Motors 8-23
DOK-ECODR3-DKC**.3-CS*-PR02-EN-P
Technical Data
Designation Symbol Unit Value
cooling type natural convection
motor overtemperature K 70 at 40 °C ambient temperature
(max. 130 °C internal temperature;
max. 110 °C surface temperature)
Electric parameters
continuous torque at standstill M
dN
Nm 2.4
continuous current at standstill I
dN
A4.3
peak current I
max
A 12.9
torque constant at 20 °C
1
)K
m
Nm/A
0.61 ±10%
voltage constant at 20 °C K
E(eff)
V/1000min
-1
37.3 ±10%
winding resistance at 20 °C R
12
1.5 ±7%
winding inductance L
12
mH
10.7 ±10%
number of pole pairs p - 4
Rated data
2
)
rated speed n
N
min
-1
3000
rated torque M
N
Nm 2.4
rated current I
N
A4.3
rated power P
N
W 754
rated voltage U
N
V 132
rated frequency f
N
Hz 200
Mechanical parameters
rotor inertia
3
)J
M
kgm² 0.67 x 10
-4
(0.75 x 10
-4
)
theoretical maximum torque M
max
Nm 7.1
minimum power strand cross section
4
)S mm
2
0.75
thermal time constant T
th
s50
maximum speed n
max
min
-1
4500
motor mass
3
) m kg 3.1 (3.8)
allowed storage and transport temp. T
L
°C -20 ... +80
allowed ambient temperature
6
)T
um
°C +0 ... +40
max. installation altitude
6
) h m 1000
degree of protection
7
) IP65 (housing); IP40 (output shaft)
insulation class (according to DIN
VDE0530 part 1)
B
housing painting none
1
)
2
)
3
)
4
)
5
)
6
)
7
)
K
m
is to be used for calculations with crest values (I
dN
, I
max
). For calculations with root-mean-square values (rated data),
the torque constant K
m
must be multiplied by a factor of
2
.
Values determined according to EN 60034-1. Current and voltage specified as root-mean-square values.
Value in brackets valid for motor with holding brake.
Applicable to REXROTH cables. Rated according to VDE0298-4 (1992) and installation type B2 according to EN 60204-1
(1993) at an ambient temperature of 40 °C.
Without blower unit:
If the limits specified are exceeded, the performance data must be reduced, if necessary.
Provided the power and encoder cables are mounted properly.
Fig. 8-30: MSM040B technical data