2000/3000 SHEET FINISHERS (B700/B701)
SM 1-69 B132/B200
Installation
4. Remove the screw [A] to release the lock lever [B] ( x 1).
5. Slowly push the finisher against the side of the machine until the brackets [D]
go into their slots. If you do this too quickly, you will bend and cause damage to
the paper-entrance guide plates [C].
6. Attach and tighten the screw removed in Step 5.
7. Connect finisher connector [E] to the main frame.
8. Attach the gasket seal [F] as shown.
Important! Check the duct
" on the left side of the
machine. Make sure that the sponge does not block this
duct.
B700I107.WMF
B132R734.WMF
[A]
[B]
[C]
[D]
[E]
[F]
"