SCANNER UNIT
SM 3-31 B132/B200
Replacement &
Adjustment
3.3.7 SCANNER WIRE
Scanner Wire Removal
1. Remove wire ground
% ( x1)
2. Disconnect the head of wire
& from tension bracket 1.
3. Remove spring '.
4. Loosen the screw ( of tension bracket 1.
5. Disconnect the end of wire at ).
6. Remove lock bracket * of the 1st scanner ( x1).
7. Disconnect the wire from the pulley + ( x1).
8. Remove the wire from the scanner.
B132R137.WMF
)
*
+