ARDF
B132/B200 6-26 SM
6.4.10 DUPLEX SCANNING
1. Side 1 of original $ is scanned, original * waits. Upper junction gate [A] opens
and sends
$ to the upper inverter rollers.
2. Original $ feeds past the upper inverter rollers [B] and stops. Upper inverter
junction gate [C] closes. The upper inverter rollers reverse and feed the original
$ into the feed path.
3. Original $ feeds to rollers [D], where skew is corrected. (!6.4.7) Skew is
corrected only for small paper sizes (B6, A5, HLT). Other sizes can be selected
for this function with SP6020.
1
3
B132D112.WMF
1
3
B132D113.WMF
1
3
B132D114.WMF
$
"
[A]
$
*
[B]
[C]
$
*
[D]