PCU
B132/B200 3-56 SM
3.5.6 TD SENSOR
Open the front door.
Remove the PCU from the machine.
[A]: Connector bracket
[B]: TD sensor
Reinstallation
After replacing the TD sensor:
Replace the developer in the PCU where the TD sensor was replaced. (!3.5.1)
Do SP3801 001~006 only for the PCU where the TD sensor was replaced.