EasyManua.ls Logo

Ricoh B132 - SC Codes Group 6: Device Communication

Ricoh B132
1079 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE CALL CONDITIONS
B132/B200 4-54 SM
SC codes Group 6: Device Communication
ARDF communication error
SC620 D
A BREAK signal occurs after the
machine detects the ARDF, or a
communication timeout occurs.
ARDF disconnected
IPU board harness disconnected,
defective
IPU board defective
Spurious noise from the power supply
line
ARDF control board defective
Mailbox-to-Finisher communication error
SC621 D
Communication between the
mailbox and finisher is
interrupted. An ACK/NCK signal
was not received within 100 ms
after a data frame is sent and 3
retries failed.
Connection cable between mailbox and
finisher disconnected, defective
Finisher main board defective
BCU defective
PSU defective
LCT communication error
SC622 D
Communication between the
copier and LCT is interrupted.
An ACK/NCK signal was not
received within 100 ms after a
data frame is sent and 3 retries
failed.
Connection cable between the LCT and
copier is disconnected, defective
LCT main board defective
BCU defective
PSU defective
Mailbox-to-copier communication error
SC624 D
Communication between the
mailbox and copier is
interrupted. An ACK/NCK signal
was not received within 100 ms
after a data frame is sent and 3
retries failed.
Mailbox cable disconnected, defective
Mailbox main board defective
BCU defective
PSU defective