ARDF
SM 6-27 B132/B200
Detailed
Descriptions
4. Side 2 of original $ is scanned, lower inverter junction gate [A] opens and
directs $ to lower inverter table [B]. Original " feeds.
5. Steps 1, 2, 3 repeat for original ". Lower inverter junction gate [C] and upper
inverter junction gate [D] remain closed. Lower inverter rollers [E] feed original
$ to exit rollers [F]
6. The exit rollers feed original $ to the original exit tray. Original " is corrected
for skew and is scanned. Skew is corrected only for small paper sizes (B6, A5,
HLT). Other sizes can be selected for this function with SP6020.
3
1
2
B132D115.WMF
B132D117.WMF
B132D118.WMF
$
"
[A] [B]
$
"
[C]
[D]
[E]
[F]
$
"